Ringkerntrenntransformatoren nach DIN EN 61558
Technische Daten
Schutzgrad: | IP00 |
Isolierklasse: | B |
Umgebungstemperatur: | max. +45°C |
Prüfspannung Wicklung-Welle: | 4 kV |
Frequenz: | 50/60 Hz |
Nenneingangsspannung: | 230 V |
Aufstellhöhe: | 1000m |
Konformität: | CE,RoHs, EAC |
Aufbau entsprechend: | VDE 0552/ DIN EN 61558-2-14 |
Auswahl RKT Eingangsspannung 230 V
Leistung in VA | Sec V 10 V |
Sec V 2x6 V |
Sec V 2x12 V |
Sec V 2x15 V |
Sec V 2x18 V |
Sec V 2x24 V |
Sec V 2x30 V |
Sec V 2x48 V |
Sec V 2x60 V |
Sec V 2x115 V |
---|---|---|---|---|---|---|---|---|---|---|
20 | X | X | X | X | X | |||||
30 | X | X | X | X | X | |||||
50 | X | X | X | X | ||||||
75 | X | X | X | X | X | X | ||||
100 | X | X | X | X | X | |||||
150 | X | X | X | X | X | |||||
200 | X | X | X | |||||||
250 | X | X | X | X | ||||||
300 | X | X | X | |||||||
400 | X | X | X | X | ||||||
500 | X | X | X | X | ||||||
630 | X | X | X | |||||||
800 | X | X | X | |||||||
1000 | X | X | ||||||||
1200 | X | X | ||||||||
1600 | X |
Abmessungen RKT
Leistung in VA | ∅ in mm | Höhe in mm | Leerlauf- spannungs- Erhöhung in % |
Gewicht in kg |
---|---|---|---|---|
20 | 61 | 32 | 18 | 0,09 |
30 | 74 | 30 | 16 | 0,16 |
50 | 79 | 37 | 14 | 0,7 |
75 | 89 | 38 | 11 | 1 |
100 | 93 | 42 | 10 | 1,25 |
150 | 97 | 51 | 9 | 1,75 |
200 | 115 | 53 | 7 | 2,3 |
250 | 118 | 55 | 7 | 2,5 |
300 | 121 | 63 | 6 | 1,23 |
400 | 131 | 64 | 6 | 3,5 |
500 | 143 | 65 | 5 | 4,3 |
630 | 145 | 77 | 5 | 5,1 |
800 | 155 | 72 | 4 | 5,5 |
1000 | 165 | 72 | 3 | 6,6 |
1200 | 195 | 72 | 3 | 7,65 |
1600 | 199 | 98 | 3 | 9,8 |