Isolating Transformer ERT 115/115 4G
Isolating transformers are used for the galvanic isolation of connected devices from the line network. Due to the special design of the ERT types according to EN 60601-1, they are suitable for use in medical applications. The devices have a grounded shield winding between the primary and secondary windings and a potential equalization bolt. The transformers are very robust and have a closed steel sheet housing. Four performance groups are available. The output current is 4A. The devices with 4A output current there are different Versions of the connections of the inputs and outputs. The necessary fusing of the devices takes place at the input and the output. In addition, the transformer windings have a temperature protection. The product is made for the US grid with 115V.
Type | ERT 115/115/4G |
---|---|
Input | 115V 50-60 Hz switchable 230V IEC-Socket |
Input current A | 4,8 |
Output | 115V switchable to 230V IEC-Socket 4x |
Output Current A | 4 / 2 |
Fuse PRI | G 5x20 4A/TT |
Fuse SEC | G 5x20 4A/T |
Protection class | I |
Protection degree | IP20 |
Power switch | 2-poles with Inrush limiter |
Energize mA | <0,3 |
Test voltage kV | 4 |
PRI-Shield kV | 2 |
SEC-Shield kV | 2 |
Ambient temperature | +40°C |
Housing | Steel sheet |
Dimensions (BxHxT) mm | 200x125x310 |
Mass kg | 11,7 |
Abrobation | CE, RoHS |
Adjustable Isolation Transformer LTS-610
Sold!
- Analog instruments (pointer and number display)
- Step less regulation of the voltage from 0 to 250 V
- Clean sine at the output
- Robust metal housing
- Security by phase separation
- Robust in use
- Extraordinary longlife
- Available in German
- Model for facelift
Price: .....€
TYPE
|
max. Current Input/Output (A) |
Mass (kg) |
Width (mm) |
High (mm) |
Depth (mm) |
LTS 610 |
12/ 10 |
40 |
460 |
230 |
320 |
Special Offers
Adjustable Isolation Transformer LTS-604
Sold!
- Analog instruments (pointer and number display)
- Step less regulation of the voltage from 0 to 250 V
- Clean sine at the output
- Robust metal housing
- Security by phase separation
- Robust in use
- Extraordinary longlife
- Available in German
- Model for facelift
Price: .....€
TYPE
|
max. Current Input/ Output(A) |
Mass (kg) |
Width (mm) |
High (mm) |
Depth (mm) |
LTS 604 |
5,5 / 4,0 |
18 |
452 |
190 |
312 |
.Adjustable Isolation Transformer LTS-604 Stainless Steel
Sold!
- Analog instruments (pointer and number display)
- Step less regulation of the voltage from 0 to 250 V
- Clean sine at the output
- Robust metal housing
- Security by phase separation
- Robust in use
- Extraordinary longlife
- Available in German
- Model for facelift with stainless steel front
Price: .....€
TYPE
|
max. Current Input/ Output(A) |
Mass (kg) |
Width (mm) |
High (mm) |
Depth (mm) |
LTS 604 |
5,5 / 4,0 |
18 |
452 |
190 |
312 |